Product Highlights

  • High Efficiency Ventilation: HPV system allows easy burner-boiler matching even with high combustion chamber pressure.
  • Dual Frequency Operation: All models support both 50Hz and 60Hz electrical frequencies for global compatibility.
  • Two-Stage Fire Safety: Optional model starts with small fire then switches to large fire to prevent deflagration.
  • Flame Monitoring System: Automatically cuts off gas and power and indicates failure upon combustion failure.
  • Easy Maintenance Design: Hinge flange allows access to combustion head without losing original settings.
  • Rotating Airflow Technology: Unique flame stabilizing disk improves air-gas mixing and combustion efficiency.
  • Comprehensive Warranty: Includes 12 months warranty coverage for mechanical defects.

Product Images of High-Efficiency 1850kw Natural Gas Burner for Industrial Use

High-Efficiency 1850kw Natural Gas Burner for Industrial Use
High-Efficiency 1850kw Natural Gas Burner for Industrial Use pictures & photos
High-Efficiency 1850kw Natural Gas Burner for Industrial Use
High-Efficiency 1850kw Natural Gas Burner for Industrial Use pictures & photos
High-Efficiency 1850kw Natural Gas Burner for Industrial Use
High-Efficiency 1850kw Natural Gas Burner for Industrial Use pictures & photos
High-Efficiency 1850kw Natural Gas Burner for Industrial Use
High-Efficiency 1850kw Natural Gas Burner for Industrial Use pictures & photos
High-Efficiency 1850kw Natural Gas Burner for Industrial Use
High-Efficiency 1850kw Natural Gas Burner for Industrial Use pictures & photos
High-Efficiency 1850kw Natural Gas Burner for Industrial Use
High-Efficiency 1850kw Natural Gas Burner for Industrial Use pictures & photos
High-Efficiency 1850kw Natural Gas Burner for Industrial Use
  • High-Efficiency 1850kw Natural Gas Burner for Industrial Use
  • High-Efficiency 1850kw Natural Gas Burner for Industrial Use
    High-Efficiency 1850kw Natural Gas Burner for Industrial Use
  • High-Efficiency 1850kw Natural Gas Burner for Industrial Use
    High-Efficiency 1850kw Natural Gas Burner for Industrial Use
  • High-Efficiency 1850kw Natural Gas Burner for Industrial Use
    High-Efficiency 1850kw Natural Gas Burner for Industrial Use
  • High-Efficiency 1850kw Natural Gas Burner for Industrial Use
    High-Efficiency 1850kw Natural Gas Burner for Industrial Use
  • High-Efficiency 1850kw Natural Gas Burner for Industrial Use
    High-Efficiency 1850kw Natural Gas Burner for Industrial Use
  • High-Efficiency 1850kw Natural Gas Burner for Industrial Use
    High-Efficiency 1850kw Natural Gas Burner for Industrial Use

Find Similar Products

Product Description

High-Efficiency 1850kw Natural Gas Burner for Industrial UseHigh-Efficiency 1850kw Natural Gas Burner for Industrial UseHigh-Efficiency 1850kw Natural Gas Burner for Industrial UseHigh-Efficiency 1850kw Natural Gas Burner for Industrial UseHigh-Efficiency 1850kw Natural Gas Burner for Industrial Use
 High-Efficiency 1850kw Natural Gas Burner for Industrial Use
 
Model A B C D E F-F(1) H I L M N O P V
E-RS 34 442 - - 422 508 216-351 140 305 138 1"1/2 84 780 - 177
E-RS 44 442 - - 422 508 216-351 152 305 138 1"1/2 84 780 - 177
E-RS 50 476 - - 474 580 216-351 152 352 164 1"1/2 108 810 719 168
E-RS 70 551 296 215 555 840 250-385 179 430 214 2" 134 1161-1296 - 221
E-RS 100 527 312 215 555 840 250-385 179 430 214 2" 134 1161-1296 - 221
E-RS 130 553 338 215 555 840 280-415 189 430 214 2" 134 1161-1296 - 221
E-RS 150 675 370 305 590 840 280-415 189 435 214 2" 134 1180-1315 - 221
E-RS 190 681 366 315 555 872 370-520 222 430 230 2" 150 1328 - 221
E-RS 250 732 427 305 555 872 370-520 222 430 230 2" 150 1328 - 262
(1) Size with extended burner head

High Power Middle Range Light Indoor Combustion Burner

It has features as below:                                                                                                  
1. Models available with different burner controllers
2. High efficiency fan ventilation system (HPV) allowing easy burner-boiler matching even with high combustion chamber pressure
3. Combustion head easy to assemble and adjust
4. The hinge flange allows easy access to the combustion head without losing the original settings 
5.All models are available to work with fifty and sixty Hz electrical frequency
6. Combustion is sufficient, high thermal power efficiency
7. Optional two-stage fire model, high safety performance. When starting, the burner will burn with small fire first, and then switch to large fire without causing deflagration.
8. Strong fuel adaptability. The burner only needs to replace a few parts to be suitable for natural gas, liquefied petroleum gas, coal gas and other types of gas.
9. The combustion status is detected by the flame monitoring system. When there is a combustion failure, the control system will issue an instruction. The solenoid valve of the air supply system will quickly close, cut off the gas and power, and indicate the failure.
10. The unique flame stabilizing disk design generates rotating airflow, which helps the air and gas to fully mix and improves combustion efficiency.
High-Efficiency 1850kw Natural Gas Burner for Industrial UseHigh-Efficiency 1850kw Natural Gas Burner for Industrial UseHigh-Efficiency 1850kw Natural Gas Burner for Industrial Use

High-Efficiency 1850kw Natural Gas Burner for Industrial UseHigh-Efficiency 1850kw Natural Gas Burner for Industrial Use
High-Efficiency 1850kw Natural Gas Burner for Industrial Use
Pre-sales Service

· Arrange professional salesmen to contact with customers timely, and understand the needs of customers preliminary.
· According to customer needs to provide professional technical support, but also canprovide video quidance and simulated experiment;
· Based on the final actual conditions to provide the best technical parameters and select the best pump type.

After-sale Service

· Once the salesman receives the customers feedback, communicate and provide the best solution timely.
· When the customer's improper operation causes the problems, the salesman should inform the customer correct use method timely;
· Salesman mail return to visits regularly and ensure every customer will satisfaction.

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI231087". Items marked "verified" are certified.

Watch Video
Watch Video
Guangdong Eacoon Energy Technology Corporation Ltd
Guangdong Eacoon Energy Technology Corporation Ltd
Guangdong Eacoon Energy Technology Corporation Ltd
Guangdong Eacoon Energy Technology Corporation Ltd
Guangdong Eacoon Energy Technology Corporation Ltd
Guangdong Eacoon Energy Technology Corporation Ltd
Guangdong Eacoon Energy Technology Corporation Ltd
Guangdong Eacoon Energy Technology Corporation Ltd

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Room 301, Building 11, Tian'an Headquarters Center, No. 555 Panyu Avenue North, Donghuan Street, Panyu District, Guangzhou, Guangdong, China
verified Plant Area
13000 square meters
verified Number of Employees
179
verified Registered Capital
50,000,000 RMB
verified Terms of Payment
LC, T/T, PayPal
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Nansha Port

Our Production Capability & Technical Expertise

verified Main Products
Burner, Alarm, Solenoid Valve
verified Production Machines
Production Line
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
22 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2002-07-04
Export Year
2016-09-27
verified Main Markets
North America, Europe, Southeast Asia/ Mideast, India
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE

FAQ

Does the burner work with different electrical frequencies?
Yes, all models are available to work with both 50Hz and 60Hz electrical frequencies.
What is the warranty period for this product?
We provide a 12-month warranty for this induction heating machine.
Is there a safety feature for combustion failure?
Yes, the flame monitoring system detects failure and automatically closes the solenoid valve to cut off gas and power.
Can I get technical support after purchase?
Yes, we offer online technical support, timely feedback solutions, and regular visits to ensure satisfaction.
Is OEM or ODM service available?
Yes, both OEM and ODM services are available for this product.
What is the maximum power output?
The maximum power is 1850kW, with a minimum power range of 300/900kW.
How long is the lead time for production?
The lead time is one month for both peak season and off-season.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now