Type |
Length(mm) |
Width(mm) |
Height(mm) |
Coil rotation(mm) |
Protection level |
MAX Pressure mbar |
DEVSG10 |
72 |
71 |
190 |
55 |
IP54 |
360 |
DEVSG15 |
72 |
71 |
190 |
55 |
IP54 |
360 |
DEVSG20 |
92 |
75 |
228 |
59 |
IP54 |
360 |
DEVSG25 |
100 |
80 |
230 |
59 |
IP54 |
360 |
DEVSG32 |
149 |
115 |
288 |
71 |
IP54 |
200 |
DEVSG40 |
149 |
115 |
288 |
71 |
IP54 |
200 |
DEVSG50 |
170 |
142 |
302 |
76 |
IP54 |
200 |
Product details
* Gas solenoid valves can be widely used in the field of gas safety transmission control to provide gas supply for
opening and closing or emergency cut-off.
* It can be applied to media such as natural gas, methane, liquefied petroleum gas etc.
* Adjustable opening time and adjustable flow.
Operation and installation
* Normally closed, it will open quickly when power is on. When operating, the blue light will go on.
* It will be closed immediately when the power is off and the light will go off.
* For the first time, you can re-adjust the factory setting mode state when the power is on, adjust the opening time and the size
of the back-end output flow, as well as the fast-open or slow-open section within the open range.
Technical parameter
Opening time:1-60 seconds
Closing time:< 1 second
Maximum operating frequency:20 times/ min
Maximum working pressure:DN10-25 360 mbar; DN32-50 200mbar
Protection level:IP54
Sealing material:NBR
Body material:Aluminum alloy for valve; AISI 302 steel spring
Working temperature:DN10-50 -15ºC ~ +60ºC; DN65-100 -20ºC ~ +60ºC
With G/4 aperture bypass holes
Built-in filtering
Standard and certification
Achieving "A"standard
Achieving EN161 standard
Meet British and European gas standards
CE certification
Electrical specification
Rated voltage: 50/60Hz, 230Vac, 110Vac, 24VDC (And other specific).
Coil level F, can be 360° rotation, can work 100% continuously for a long time.
Pre-sales Service
· Arrange professional salesmen to contact with customers timely, and understand the needs of customers preliminary.
· According to customer needs to provide professional technical support, but also canprovide video quidance and simulated experiment;
· Based on the final actual conditions to provide the best technical parameters and select the best pump type.
After-sale Service
· Once the salesman receives the customers feedback, communicate and provide the best solution timely.
· When the customer's improper operation causes the problems, the salesman should inform the customer correct use method timely;
· Salesman mail return to visits regularly and ensure every customer will satisfaction.